Download Print this page

Ricoh V-C3 Technical Training Manual page 406

Advertisement

When is Toner Supply Adjusted? - 1
! At the end of each job
Slide 406
No additional notes
" Done if the number of pages since the previous
process control is more than the value of SP
3551 001 (black-and-white, default 250) or SP
3551 002 (colour, default 250).
" This uses the development gamma that was
calculated during potential control.
» If the development gamma during process control is too
low, the toner concentration is increased.
» If the development gamma during process control is too
high, the toner concentration is decreased.
406