Goodrive300-01A series VFD for air compressor
Function
Name
code
Speed display
P03.27
selection in
vector control
IF starting
P03.28
current
Inductance
P03.29
coefficient
P04 group SVPWM control
Function
Name
code
V/F curve
P04.00
setting of
motor 1
Torque boost
P04.01
of motor 1
Torque boost
P04.02
cut-off of motor
V/F frequency
P04.03
point 1 of
motor 1
V/F voltage
P04.04
point 1 of
motor 1
V/F frequency
P04.05
point 2 of
motor 1
V/F voltage
P04.06
point 2 of
motor 1
V/F frequency
P04.07
point 3 of
motor 1
V/F voltage
P04.08
point 3 of
motor 1
0: Display the actual value
1: Display the set value
0–100.0% (of the motor rated current)
0.2–40.0
0: Straight-line V/F curve
1: Multi-point V/F curve
2–5: Reserved
0.0%: (automatic); 0.1%–10.0%
0.0%–50.0% (relative to rated frequency of
motor 1)
1
0.00Hz–P04.05
0.0%–110.0% (of the rated voltage of motor
1)
P04.03–P04.07
0.0%–110.0% (of the rated voltage of motor
1)
P04.05–P02.02
P04.05–P02.16
0.0%–110.0% (of the rated voltage of motor
1)
Description
Description
(rated frequency of AM 1)
(rated frequency of SM 1)
-46-
Function description
Default
Modify
○
0
○
60.0%
○
1.0
Default
Modify
◎
0
○
0.0%
○
20.0%
○
0.00Hz
○
00.0%
○
00.00Hz
○
00.0%
○
00.00Hz
○
00.0%
Need help?