INVT Goodrive300-01A Series Operation Manual page 95

Hide thumbs Also See for Goodrive300-01A Series:
Table of Contents

Advertisement

Goodrive300-01A series VFD for air compressor
Function
Name
code
Present
P19.21
auxiliary
temperature
Input power
phase
P19.22
sequence
state
Description
Present
auxiliary
pressure Mpa
P18.37=0
P18.38
P19.20
0
P05.42
Present auxiliary
pressure Mpa
P18.37=1
P18.04
P19.20
0
P05.32
Range: 0.00–655.35Mpa
Display the
auxiliary
detected at present.
Present auxiliary
P18.03=0
temperature
150
120
P19.21
20
0
P18.32
-20
Present auxiliary
temperature
P18.03=1
150
120
P19.21
20
0
P18.28
-20
Range: -20–150° C
If the VFD enables phase sequence detection
and input phase loss hardware protection,
corresponding fault will be reported when
negative sequence and any phase loss
occurs; otherwise, fault will not be reported.
0: Positive sequence
-89-
P17.21
P05.44
P2 input
voltage
P17.19
P05.34
P1 input
voltage
temperature
value
P18.33
P17.22
PT2 input
voltage
P18.29
P17.20
PT1 input
voltage
Function description
Default
Modify
0℃
0