Goodrive300-01A series VFD for air compressor
Function
Name
code
P06.01
RO5 output
P06.02
RO3 output
RO1 output
P06.03
RO2 output
P06.04
Output
terminal
P06.05
polarity
selection
Description
3: Running reversely
4: Jogging
5: VFD in fault
6: FDT1
7: Reserved
8: Frequency reached
9: Running in zero speed
10: Upper limit frequency reached
11: Lower limit frequency reached
12: Ready for running
13: Pre-exciting
14: Overload pre-alarm
15: Underload pre-alarm
16–19: Reserved
20: External fault is valid
21–22: Reserved
23: Modbus communication virtual terminal
output
24–26: Reserved
27: Fan running control (only for air
compressors)
28: Loading valve control output (only for air
compressors)
29: Master cooling fan control
30: System fault (only for air compressors)
31: Water shut-off valve control (only for water
lubrication)
32: Water replenishing valve control (only for
water lubrication)
33: Water discharging valve control (only for
water lubrication)
34: Water heater valve control (only for water
lubrication)
35: Emptying valve control (water lubrication/
acetylene)
The function code is used to set the polarity of
output terminals.
When a bit is 0, the input terminal is positive;
when a bit is 1, the input terminal is negative.
-52-
Function description
Default
Modify
0
0
0
0
0