Goodrive300-01A series VFD for air compressor
Category Terminal
RO5A
RO6A
ROC
J3
Jumper
terminal
J4
Ia
Current
Ib
input
Ic
B.1.2 Assembly instruction
1. Remove the cover and keypad.
Name
relay 4
NO contact of
relay 5
NO contact of
relay 6
Common contact
of relay 3–6
P1- analog signal
I corresponds to current signal, V corresponds to
selection terminal
voltage signal, and the default is current input signal.
Internal/external
You can select internal power (NPN mode) or external
power selection
power (PNP mode) through J4. The default is internal
terminal
power (NPN mode).
A phase current
1. Range: 0–40A
input of the fan
2. Error: ± 3%, 25℃
B phase current
3. Input impedance: 50Ω
input of the fan
4. Recommended transformation ratio of the current
C phase current
transformer: 200 or 1000
input of the fan
Description