Goodrive300-01A series VFD for air compressor
P17 group Status viewing
Function
Name
code
P17.00
Set frequency
Output
P17.01
frequency
Ramp
P17.02
reference
frequency
P17.03
Output voltage 0–1200V
P17.04
Output current 0.0–3000.0A
P17.05
Motor speed 0–65535RPM
P17.06
Torque current -3000.0–3000.0A
Excitation
P17.07
current
P17.08
Motor power
P17.09
Output torque -250.0–250.0%
Estimated
P17.10
motor
frequency
P17.11
DC bus voltage 0.0–2000.0V
Digital input
P17.12
terminal status
Digital output
P17.13
terminal status
Master fault
P17.16
code
P17.17
Reserved
Auto fault reset
P17.18
count of
present fault
P1- input
P17.19
voltage
Description
0.00Hz–P00.03
0.00Hz–P00.03
0.00Hz–P00.03
-3000.0–3000.0A
-300.0%–300.0% (relative to rated motor
power)
0.00–
P00.03
0000–00FF
0000–000F
0–43 (see
P07.27–P07.32
0–1000
0–20
Display analog input voltage value of P1-
channel, 2.00V–10.00V corresponds to 4–
20mA;
P05.32–P05.34
pressure 0.0–P18.04. If P1- input voltage is
larger than 9.8V or less than 1V, it indicates
pressure signal fault occurs.
Range: 0.00–10.00V
-74-
for details)
correspond
to
Function description
Default
Modify
●
0.00Hz
●
0.00Hz
●
0.00Hz
●
0V
●
0.0A
●
0 RPM
●
0.0A
●
0.0A
●
0.0%
●
0.0%
●
0.00Hz
●
0V
●
0
●
0
●
0
●
0
●
0
●
0.00V