P06 Group Output Terminals - INVT Goodrive300-01A Series Operation Manual

Hide thumbs Also See for Goodrive300-01A Series:
Table of Contents

Advertisement

Goodrive300-01A series VFD for air compressor
Function
Name
code
P2 input filter
P05.46
time
P05.47
PT2 lower limit
Corresponding
P05.48
setting of PT2
lower limit
PT2 upper
P05.49
limit
Corresponding
P05.50
setting of PT2
upper limit
PT2 input filter
P05.51
time
P1 analog
P05.52
input type
selection
P2 analog
P05.53
input type
selection

P06 group Output terminals

Function
Name
code
RO4 output
P06.00
Description
0.000s–10.000s
0.00V–P05.49
-100.0%–100.0%
P05.47–10.00V
-100.0%–100.0%
0.000s–10.000s
0: Voltage
1: Current
Note: When switching the P1 analog input
type, it is necessary to ensure that the
position of P1 jumper cap on the main control
board is correct. In addition, you need to
modify P05.52, otherwise deviation may
occur in the accuracy of the P1 analog input.
0: Voltage
1: Current
Note: When switching the P2 analog input
type, it is necessary to ensure that the
position of P2 jumper cap on the expansion
board is correct. In addition, you need to
modify P05.53, otherwise deviation may
occur in the accuracy of the P2 analog input.
Description
0: Disable
1: Running
2: Running forward
-51-
Function description
Default
Modify
0.200s
0.00V
6.3%
10.00V
75.0%
0.300s
1
1
Default
Modify
0