Goodrive300-01A series VFD for air compressor
Function
description
VFD state word
1
VFD state word
2
Address
definition
BIT3: =1 running time of part 4 cleared to
BIT4: =1 running time of part 5 cleared to
BIT5: =1 device running time cleared to
BIT6: =1 solenoid valve loading =0:
solenoid valve unloading
The set maintenance time of part 1;
2010H
Range: 0–65535
The set maintenance time of part 2;
2011H
Range: 0–65535
The set maintenance time of part 3;
2012H
Range: 0–65535
The set maintenance time of part 4;
2013H
Range: 0–65535
The set maintenance time of part 5;
2014H
Range: 0–65535
2015H
Running time of part 1, 0–65535
2016H
Running time of part 2, 0–65535
2017H
Running time of part 3, 0–65535
2018H
Running time of part 4, 0–65535
2019H
Running time of part 5, 0–65535
201AH
Running time of the device: 0–65535
Start/stop command of power-frequency
201BH
fan, 0–3
0001H: In forward running
0002H: In reverse running
0003H: In stopping
2100H
0004H: In fault
0005H: VFD Poff state
0006H: VFD pre-exciting state
Bit0: =0: Not ready to run =1: Ready to run
Bi1–2: =00: Motor 1
2101H
Bit3: =0: Asynchronous motor
=1: Synchronous motor
Data meaning
zero =0: invalid
zero =0: invalid
zero =0: invalid
=01: Motor 2
=10: Motor 3
=11: Motor 4
-173-
Communication protocol
R/W
characteristics
W
W
W
W
W
W
W
W
W
W
W
W
R
R