INVT Goodrive300-01A Series Operation Manual page 155

Hide thumbs Also See for Goodrive300-01A Series:
Table of Contents

Advertisement

Goodrive300-01A series VFD for air compressor
B.2.4.11 Fan parameter interface
1. Enter the fan parameter interface through the main menu.
Fan parameter
Rated fan current
Fan current transfer
ratio
Current imbalance
coefficient
Phase A current
calibration coefficient
03.17 16:02:35
Set value
Max. 010.00 s
Min. 000.00 s
Return
Figure B-38 Figure B-38 Differential time setting interface
03.17 16:02:35
Rated Fan Current
Fan Current Transfor Ratio xxxx.x
Current Imbalance Coeffi
Phase A Cur Calib Coeffi
Phase B Cur Calib Coeffi
Phase C Cur Calib Coeffi
Return
Figure B-39 Figure B-39 Fan parameter interface
Initial value
0.0A
1000.0
1.60
100.0%
Differential time
xx.x
x
s
Home
Fan param
xxxx.x A
xxx.xx
xxxx.x %
xxxx.x %
xxxx.x %
Home
It is associated with the power-frequency fan current
detection and overload protection functions. It is valid
only when the value is not 0, and it is invalid when the
value is 0.
Setting range: 0–40.0
Setting range: 1.0–4000.0
When ratio of the maximum current to the minimum
current among the fan three-phase currents is greater
than this value, the VFD reports the fan current
unbalance fault.
Setting range: 1.00–3.00
Actual current = Displayed current * Current coefficient
factor
-149-