Maintenance Activities, Controller Irc5; Maintenance Schedule, Controller Irc5 - ABB IRC5 Product Manual

Robot controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

3 Maintenance activities, controller IRC5

3.1. Maintenance schedule, controller IRC5

General
The IRC5 robot controller must be maintained at regular intervals to ensure its function. The
maintenance activities and their respective intervals are specified below:
Intervals
Equipment
Complete
controller modules
Moist dust filter
Moist dust filter
Heat exchanger
fan
Heat exchanger
fan
FlexPendant
Earth Fault
Breaker
*) The time interval depends on the working environment of the equipment: a cleaner
environment may extend the maintenance interval and vice versa.
3HAC021313-001 Revision: P
3 Maintenance activities, controller IRC5
3.1. Maintenance schedule, controller IRC5
Maintenance
Interval
activity
Inspection
12 months *
Cleaning
Replacement
24 months *
Inspection
6 months *
Cleaning
12 months *
Cleaning
When needed
Testing
6 months
Detailed in
Note!
section:
Inspection of the
controller on
page
168.
Cleaning moist
dust filter on
page 175
Replacement of
moist dust filter
on page 171
Inspection of the
controller on
page
168.
Cleaning of the
controller
cabinet on page
174.
Cleaning the
FlexPendant on
page
176.
Contact ABB for
more information
167

Hide quick links: