Upgrading And Installation Of 2X Euromap Interface (Option 671-4) - ABB IRC5 Product Manual

Robot controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

2.9.8. Upgrading and installation of 2X Euromap interface (Option 671-4)

General
This section describes installation of 2X Euromap interface (Option 671-4) in an IRC5 Single
Cabinet Controller and in an IRC5 Dual Cabinet Controller. The customer option 2X
Euromap interface is not a pre mounted delivery option, it must be complimented with a
safety relay, not included in the option kit from ABB.
NOTE!
The 2X Euromap interface (Option 671-4) is an upgrade option and demands a pre installed
Euromap installation.
NOTE!
The harness used when installing 2X Euromap is identical with the pre mounted Euromap 1
harness. Beware of the identical connection markings.
Location of Euromap 2X interfaces in the Single Cabinet Controller
xx0800000214
A
B
C
D
E
3HAC021313-001 Revision: P
2.9.8. Upgrading and installation of 2X Euromap interface (Option 671-4)
Connector A21.X5, on panel board
Connector A21.X1, on panel board
Connector A21.X2, on panel board
Relay 24K1 and relay 24K2
2X Euromap 67: Digital 24 VDC I/O
2 Installation and Commissioning, IRC5
Continues on next page
125