A-20
Service Conditions
1.
A maximum of 10 digits for AUTHORIZATION CODE can be dialed, and 8 digits will be registered on
STATION MESSAGE DETAIL RECORDING [S-10].
2.
The maximum number of AUTHORIZATION CODES is 4,000. This number is dependent upon system
configuration.
These specifications are based on the digits being assigned as follows:
1st digit:
2nd digit:
3rd digit:
4th digit:
5th - 8th digits:
9th & 10th digits:
Note:
See ETI: 082 for details on AUTHORIZATION CODE/FORCED ACCOUNT CODE [F-7] assignment.
3.
Service set tone is common to AUTHORIZATION CODE, ACCOUNT CODE [A-18] and FORCED
ACCOUNT CODE [F-7], but can be eliminated by system data as required.
4.
AUTHORIZATION CODE and FORCED ACCOUNT CODE [F-7] cannot be provided simultaneously
for the same tenant group. System data determines, on a per-tenant basis, whether AUTHORIZATION
CODE or FORCED ACCOUNT CODE [F-7] is used.
5.
AUTHORIZATION CODE dialing (Procedure 1) is also effective with CONSULTATION HOLD [C-
17]. Special dial tone is received instead of dial tone after AUTHORIZATION CODE.
6.
Procedure 2 is effective only for LEAST-COST ROUTING - 3/6-DIGIT [L-5] calls.
7.
Stations must be assigned for Procedure 1 and 2 via CLASS OF SERVICE - INDIVIDUAL [C-5]
programming in system data.
8.
In Procedure 1, system data can determine, on a per-tenant basis, whether or not an ACCOUNT CODE
[A-18] follows the AUTHORIZATION CODE.
9.
Assigned AUTHORIZATION CODES can be used for the REMOTE ACCESS TO SYSTEM [R-2]
function.
10.
OG TRUNK QUEUING [O-2] and OFF-HOOK QUEUING [O-7] can be set according to the Service
Feature Class of the user's AUTHORIZATION CODE.
11.
AUTHORIZATION CODE can be recorded in the STATION MESSAGE DETAIL RECORDING [S-10]
for Procedure 2.
12.
The registered/non-registered condition of the AUTHORIZATION CODE is not included in the
information block of Condition B on the SMDR output format.
13.
Attendant cannot activate this feature by Procedure 1.
14.
When the user goes on-hook or hooking, changed class goes back to normal class.
15.
See Service Conditions for the AUTHORIZATION CODE DISPLAY ELIMINATION [A-99].
Interactions
1.
If FORCED ACCOUNT CODES [F-7] are used, AUTHORIZATION CODES are not used within the
same tenant.
2.
AUTHORIZATION CODES may be used in conjunction with ACCOUNT CODES [A-18].
3.
When assigning an AUTHORIZATION CODE Restriction of 1 in AATC, the RSC must be constructed
in ARSC.
4.
AUTHORIZATION CODES can be unrestricted or assigned one of 15 Route Restriction Classes.
Page 30
Authorization Code
A (when A equals a unique digit from 0 - 9)
B - C (when b, c equal any two unique digits from 0 - 9)
D-E (when d, e equal any two unique digits from 0 - 9)
F-G-H (when f, g, h equal any three unique digits from 0 - 9)
Any combination 0 - 9
Assigned using the checksum. These are for validation purposes only.
See ETI: 091 for more details.
NEAX2400 IPX Feature Programming Manual