NEC NEAX2400 IPX Programming Manual page 831

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

V-1
Interactions
1.
To calculate VARIABLE TIMING PARAMETERS, multiply the Timer Class by the Miscellaneous
Timer Class, TC x MTC = VARIABLE TIMING PARAMETER. TC is a set value. MTC is any value
from 1-15, assigned in hexadecimal. For the PERIODIC TIME INDICATION TONE Timer, a TC of 3
equaling 2 seconds is not available, but a TC of 4 equaling 30 seconds is available.
Timer Index:
Bit
TC values for Indexes 136, 147, 150, 155, 156, 157, 158
TC 0 = -
1 = -
2 = -
3 = 2 seconds.
TC values for Indexes 134, 139, 140, 141, 152
TC 0 = -
1 = -
2 = -
3 = 2 seconds
7 = 8 seconds.
TC values for Indexes 137, 146
TC 0 = -
1 = 64 milliseconds
2 = -
3 = 2 seconds
4 = 30 seconds.
TC values for Indexes 138
TC 0 = -
1 = 64 milliseconds
2 = -
3 = 2 seconds
4 = 30 seconds
5 = 5 minutes
6 = 1 second.
Timer Index:
Bit
Page 788
Variable Timing Parameters
7
6
5
4
Timer Class (TC)
7
6
5
4
Timer Class (TC)
3
2
1
0
Miscellaneous Timer Class
(MTC)
3
2
1
0
Miscellaneous Timer Class
(MTC)
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1