S-24D
S-24D
General Description
This feature allows for a D
Operating Procedure
1.
Go off-hook, seize any idle line, and dial a number.
2.
When the number has been dialed, press the SAVE AND REPEAT (S&R) feature key. The dialed number
is stored for future use. The associated LED lights. The LCD displays:
Note:
Dialed number displays only 16 digits (16DC, 24DS) when monitoring. However, 24 digits can actually be
stored in memory.
3.
To access this number later, go off-hook, receive dial tone, and press the S&R key; the saved number is
dialed.
Service Conditions
1.
One number per station can be saved.
2.
The save function may be set at any time after the number has been dialed and before going on-hook.
3.
It is not necessary to erase a saved number in order to save another. The second number replaces the first.
term
4.
A D
user may save the number of an incoming call, if the call originates at a station in the system. A
call from an outside trunk cannot be saved.
5.
If necessary, dialing can be added after a repeat operation.
6.
To monitor the saved digits, press the S&R key while idle. The saved digits will be displayed on the LCD.
7.
If the LED associated with S&R goes out, the memory is erased. The S&R key must be pressed again,
using the above procedure, to retain the original memory.
8.
To memorize the telephone number of the calling station, assign SYS1, Index 641, b0=1 (Telephone
Number is available) by the ASYDL command.
9.
When activating this feature via FCCS using a D
recommended:
Note:
If the above mentioned card is not used, the Caller ID Service is not provided and the telephone number and
more than six digits of the calling station number cannot be saved.
10.
When activating this feature via FCCS, the calling number from an outside trunk can be saved, when the
calling number information was received.
Page 700
Save And Repeat - D
Save And Repeat - D
term
set to save a specific dialed number and then redial that number later.
S&R
(Time Display)
FUNCTION NAME
16ELC
DAI
2DAI
term
Example: Saved Local Number
9-NXX-XXXX
term
Series E, the following circuit cards are
PA-DAIG, PA-DAIH, PA-DAIJ
term
CIRCUIT CARD
PA-16ELCJ
PA-2DAIK
NEAX2400 IPX Feature Programming Manual