NEC NEAX2400 IPX Programming Manual page 582

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

N-1
General Description
This feature routes calls normally directed to the ATTENDANT CONSOLE [A-3] to a preselected common station
within the system when the Night Mode has been entered.
Operating Procedure
To answer NIGHT CONNECTION calls
1.
The incoming calls to the ATTENDANT CONSOLE [A-3] in the night mode are automatically
transferred to a preselected NIGHT CONNECTION - FIXED station.
2.
Calling party hears ringback tone.
3.
Ring signal is sent to the NIGHT CONNECTION - FIXED station.
4.
NIGHT CONNECTION - FIXED station goes off-hook to answer the incoming call. If necessary, this
station can transfer the incoming call to another station within the system, using CALL TRANSFER -
ALL CALLS [C-11] feature.
Service Conditions
1.
Calls that are being processed or are in the hold state when the night mode is entered, continue being
processed or held after the mode changeover has been completed.
2.
If the NIGHT CONNECTION - FIXED station, to which an incoming call has been directed is busy, the
calling party will hear ringback tone until the station becomes idle.
3.
This service feature may be provided with NIGHT CONNECTION - FLEXIBLE [N-2] and TRUNK
ANSWER FROM ANY STATION [T-8] in the same system.
4.
If the NIGHT CONNECTION - FIXED station is set for CALL FORWARDING - ALL CALLS [C-5],
incoming Central Office trunk calls terminated to that station will be forwarded to the designated station.
5.
Programmed NIGHT CONNECTION - FIXED stations can use CALL HOLD [C-6], CALL TRANSFER
[C-10, 11] and THREE-WAY CALLING [T-2] provided these features are programmed into its CLASS
OF SERVICE - INDIVIDUAL [C-15].
6.
Only Ring Down (COT) incoming calls will be routed to NIGHT CONNECTION - FIXED stations.
7.
If an incoming call has terminated to a NIGHT CONNECTION - FIXED, and if the station is busy or in
LINE LOCKOUT [L-3], the call will be forwarded to the TRUNK ANSWER FROM ANY STATION
(TAS) [T-8] unit, if equipped.
8.
When activating this feature within an FCCS network, the different destination for C.O. incoming calls
(Ring down) cannot be set at each tenant group.
Interactions
1.
The Night station is assigned to each trunk, and the same NIGHT CONNECTION - FIXED can be
assigned to several trunks.
2.
All trunks to be terminated at the NIGHT CONNECTION - FIXED station must be programmed in ACSI.
Refer to DIRECT-IN TERMINATION
3.
The system must enter Night mode. Refer to ATTENDANT CONSOLE
OF SERVICE [D-15].
4.
The Attendant Console must first be provided.
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Night Connection - Fixed
Night Connection - Fixed
[D-7]
for more information on DITs.
[A-3]
and DAY/NIGHT CLASS
N-1