Service Conditions (cont'd)
6.
Traffic measurement duration time is designated for more than one hour. If the traffic measurement
duration time is not designated, the measurement is performed indefinitely until a stop command is entered
on the MAT [M-18].
Station Peg Count
Route Peg Count
ATT Peg Count - Incoming
ATT Peg Count - Answer
Interactions
If the system is reset, traffic measurement requests are no longer in service.
Programming
To Order PEG COUNTS
STEP 1:
ASYD - System Data 1, Index 47, bit 7 = 1.
STEP 2:
ASTD - STM:7, STS:0, ST:1.
STEP 3:
ATRF - Assignment of Traffic Measurement Order
TYPE:
INTERVAL: Output Interval must be assigned in units of 10 minutes. Available range is from 30-120
minutes or "0" must be assigned.
FROM-TO-: Measurement to be designated.
TIME:
TYPE:
To Display PEG COUNT Information
STEP 1:
DTF1 - Display of Traffic Data 1
TYPE:
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
PEG COUNT
Type of Traffic Measurement
Output Time
1:
Terminal Traffic Measurement
2:
Route Traffic Measurement
3:
Station Peg Count
4:
Attendant Console Peg Count
5:
Route Peg Count
6:
Service Peg Count
8:
UCD Route Peg Count
9:
UCD Group Peg Count
10:
UCD Station Peg Count
11:
CCIS Traffic Count
Type of Traffic Measurement
1:
Terminal Traffic
2:
Route Traffic
3:
Station Peg Count
4:
ATT Peg Count
5:
Route Peg Count
Peg Count
NEAX2400 IPX
TN = 1-255
RT = 1-255
TN = 1-255
ATT = 1-16
P-7