NEC NEAX2400 IPX Programming Manual page 816

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

Service Conditions (cont'd)
10.
When the Timed Reminder cancel code is dialed, the user hears Service Set Tone or the announcement
even when the service is not set.
Programming
STEP 1:
ASYD - System Data 1, Index 162, bits 6 and 7 tone type when a Timed Reminder call is answered.
b7
b6
0
0 = Music-On-Hold
Note:
When Music-On-Hold is selected, STEPs 5 through 8 are not required.
System Data 1, Index 163, bit 7. Start time for Timed Reminder/Wake Up Call 0/1 = On time / 5min.
earlier the appointed time.
System Data 1, Index 169, bits 4. through 7. Maximum advancing time for Timed Reminder calls,
which becomes effective when the number of stations which have appointed the same time exceeds the
threshold value (maximum 500 STNs per LP or CPU). This value is set as follows.
5x N (min.)N ranges 0 to F (Hex).
STEP 2:
ASFC - Allow this feature to proper service feature classes (SFI = 41). 0/1 = Restricted / Allowed
STEP 3:
ASPA - Assign the following two access codes for this feature.
Timed Reminder (SET):SRV = SSC (Service Code), SID = 48
Timed Reminder (CANCEL):SRV = SSC (Service Code), SID = 49
STEP 4:
ARTD - Assign route data for announcement trunk(s).
STEP 5:
ATRK - Assign trunk data for the announcement trunk(s).
STEP 6:
MBTK - Make idle the assigned trunk(s).
STEP 7:
ARSC - Allow the connection between the assigned trunk(s) and stations.
STEP 8:
AAED - Assign announcement equipment data.
EQP
= 16 (Timed Reminder Set-up Message)
EQP
= 18 (Timed Reminder Cancel Message)
EQP
= 22 (Timed Reminder/Wake Up Call Message for Announcement Trunk)
C:
Duration of Connection
0/1:Disconnected in 30 sec./ Until the station releases
R:
Sending Ring Back Tone
0/1: To be sent / Not to be sent
A:
Answer Signal Sending
0/1: No answer from in coming trunk / Answer from incoming trunk
M:
Multiple Connection
0/1: Single / Multiple Connection
RT:
Route Number TK:
Standard programming is as follows:
C = 1, R = 1, A = 0, M = 1
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Timed Reminder
b7
b6
0
1 = Announcement
Trunk Number
T-62
Page 773