NEC NEAX2400 IPX Programming Manual page 843

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

A-44
Operating Procedure (cont'd)
When the opposite end DTE disconnects when using keyboard dialing
1.
When the opposite end DTE releases, the Data Adapter buzzer will sound three times.
2.
Enter release command RLS and press the RETURN key. The monitor will display RLS and RELEASED.
3.
The data connection is released.
Service Conditions
1.
Data terminals up to 19.2 Kbps can be connected.
Additional hardware is required for 19.2 Kbps.
Note:
2.
A data terminal can be a member of a Pilot Hunt group or a Circular Hunt group.
3.
The calling and called DTEs must be code and speed compatible.
4.
Keyboard dialing can only be utilized by a D
5.
Additional hardware is required to activate KEYBOARD DIALING - DATA ADAPTER [K-1].
6.
If keyboard dialing is used to establish a data connection, keypad dialing for a data connection is
ineffective until the data connection releases. If data communication is established by keypad dialing, it is
possible to release by keyboard dialing.
7.
The display of the DTE will be blank when data communication is established by keypad dialing. The
display of the D
8.
The DSPY/AUTO key on the D
9.
When an incoming data call is received, the displays of the DTE and the D
the calling data station or the incoming trunk type and number.
Interactions
When assigned, the DATA feature key acts as the telephone number of the data station for the Data Adapter. The
telephone number of the data station will only appear on one D
may be used as a DID number.
Programming
For Data Adapter
STEP 1:
ASDT - Assign levels 4, 5, 6, & 7 of a PA-4DLC as a TEC = 13. Data level 4 corresponds to voice
level 0, level 5 to level 1, level 6 to level 2, level 7 to level 3.
TN:
Tenant Number
STN:
Station Number
LENS: Line Equipment Number (6 digits)
TEC:
Telephone Class (1-31)
1: DP (10pps)
2: PB
3: DP/PB
11: VMM
12: D
13: Data terminal Via D
14: Hot Line
15: CAS Line
Page 800
Asynchronous Data Switching - CCIS
term
will be blank when data communication is established via keyboard dialing.
term
is ineffective when keyboard dialing is used to establish a data call.
term
term
term
/Data Adapter or asynchronous Data Module.
term
set. The telephone number of the data station
NEAX2400 IPX Feature Programming Manual
term
will show the number of
NDA-24297, Issue 1