FCCS Programming (cont'd)
STEP 4:
ARRCN - Assign to the system trunk-to-trunk connection. Use Alternative Route Index (ARI-D-RES)
for Direct Connection. Three possible Restrictions may be assigned; data "0", Connection is
Restricted; data "1", Connection is Allowed; or data "2", Toll Restriction is required. For TANDEM
SWITCHING OF TIE TRUNKS-2/4 WIRE, TOLL RESTRICTION is not required.
STEP 5:
APADN - Assign any Pad data that may be required for desired quality of service. (Optional, see TIE
LINE CONNECTION WITH PAD CONTROL [T-5]).
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Tandem Switching of TIE Trunks - 2/4-Wire