NEC NEAX2400 IPX Programming Manual page 427

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

H-9
Interactions
SPEED CALLING-SYSTEM [S-3] must first be provided.
Programming
STEP 1:
ASYD - System Data 2, Index 1, Bit 7. Does TOLL RESTRICTION apply to SPEED CALLING-
SYSTEM [S-3]? 0/1: Yes/No. If TOLL RESTRICTION applies, construct an RSC that will allow the
station access to the outgoing number.
STEP 2:
ASFC - Construct a Service Feature Class that allows Service Feature Index (SFI) 12; SPEED
CALLING-SYSTEM [S-3]. Assign this SFC to the Hotline station.
If using a Virtual Circuit (TEC = 18) for the hotline, SFI: 36 (Special Common Battery/Hotline) must
be set to "1" for the Virtual Circuit's SFC.
STEP 3:
ASDT - Assign the HOTLINE-OUTSIDE station as a TEC = 18, Virtual Circuit or TEC = 14, Hotline.
TN:
Tenant Number
STN:
Station Number
LENS: Line Equipment Number (6 digits)
TEC:
Telephone Class (1-31)
1: DP (10pps)
2: PB
3: DP/PB
12: D
13: Data terminal Via D
14: HOTLINE
15: CAS Line
18: Virtual Circuit
23: ISDN Terminal
27: Eight Conference Equipment
RSC:
Route Restriction Class (0-15)
For assignment of RSC, ARSC command.
SFC:
Service Feature Class (0-15)
For assignment of SFC, ASFC command.
STEP 4:
ASPD - Assign the Tenant Number, the Abbreviated Digit Code-ADC, and the CD-Telephone
Number to be sent. Include in the CD the access code of the route.
STEP 5:
AHLS - Assign the HOTLINE-OUTSIDE station with the following parameters:
HOT TN: HOTLINE-OUTSIDE Tenant
STN:
TYPE:
CON TN: Connecting Stations Tenant. Assign same TN # as in HOT TN:
ADC:
Page 384
Hotline - Outside
term
term
HOTLINE-OUTSIDE Station
2 (ADC)
Abbreviated Digit Code of Corresponding Outside Number.
NEAX2400 IPX Feature Programming Manual