Volkswagen CJDA Workshop Manual page 99

Industrial engine
Table of Contents

Advertisement

Indicated on display
Electrical fault
09327/P246F
Exhaust gas temperature
sender 4, bank 1
Implausible signal
09328/P2470
Exhaust gas temperature
sender 4, bank 1
Short to earth
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
Possible cause of fault Possible effects
◆ Open circuit or line
short-circuit
◆ -G648- defective
◆ Open circuit or line
short-circuit
◆ -G648- defective
◆ Wiring short to earth
◆ -G648- defective
Industriemotoren - Industrial Engines 2009 ▶
◆ Regeneration of die-
sel particulate filter
locked
◆ No limitation
◆ Regeneration of die-
sel particulate filter
locked
3
Fault remedy
– -G648- Check.
⇒  P age 444
– Pull off temperature
sensor, and measure
reference volt-
age (3.3 V) on signal
line, measured value
block => connect sig-
nal line to earth, if
sensor raw voltage in
measured value block
= 0 V => sensor de-
fective => sensor raw
voltage in measured
value block ap-
prox.=0 V => check
sensor wire to ECU
– Wire to ECU OK, ECU
defective
– -G648- Check.
⇒  P age 444
– Comparison of all
temperatures with
completely cooled
down engine and ter-
minal 15 ON / engine
OFF. Electr. test of
sensor wires;
– -G648- Check.
⇒  P age 444
– Pull off temperature
sensor => sensor raw
voltage in measured
value block "Exh_uR-
awTPFltDs" approx.
reference voltage
(3.3 V) => sensor de-
fective, sensor raw
voltage in measured
value block approx.
0 V => check wire to
ECU
– Wire to ECU OK, ECU
defective
3 List of fault codes