Volkswagen CJDA Workshop Manual page 454

Industrial engine
Table of Contents

Advertisement

3
Industriemotoren - Industrial Engines 2009 ▶
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
◆ Current flow diagram
Test prerequisites
● Fuses must be OK.
● The battery voltage must be at least 11.5 V.
● All electrical consumers must be switched off.
● Earth connections OK
● Coolant temperature must be at least 80°C, ⇒ display group
1, display zone 4.
Test procedure
Note
◆ The exhaust gas recirculation valve -N18- and exhaust gas
recirculation potentiometer -G212- are installed in one com-
mon housing.
◆ Only gold-plated contacts may be used when repairing the
contacts in the connector of the exhaust gas recirculation
valve.
– Connect vehicle diagnostic tester, and select engine control
⇒  P age 23
unit.
– Select diagnosis function "015-Access permissions".
– Carry out final control diagnosis, and activate exhaust gas
recirculation valve -N18-
The displays in display zones 3 and 4 must fluctuate within fol-
lowing control range:
● Specification in display zone 3: 180...470 mg/stroke
● Specification in display zone 4: 70...100%
Note
The activation of the valve can also be checked by touching it.
– Proceed with final control diagnosis until completed.
– Exit diagnosis function.
– Switch off ignition.
If the valve is not activated:
– Pull off 6-pin connector on exhaust gas recirculation valve
-N18- with exhaust gas recirculation potentiometer -G212-
⇒  P age
-3-
433.
Checking voltage supply
– Switch on ignition.
438
Repair Group 26 - Exhaust system
⇒  P age
89, final control diagnosis.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

CjddCpyaCpybCpycCpydCpye

Table of Contents