Industriemotoren - Industrial Engines 2009 ▶
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
Display
Operating mode or component
zone
1
Glow plug system status
2
Glow period (in seconds)
3
Voltage supply from automatic glow peri-
od control unit
4
Coolant temperature
Evaluation: display group 12, display zone 1 - glow plug
system status
Note
Meaning of figures in 8-digit number block for status of glow
plug system:
Significance if display = 1
Dis-
Glow plug system status
play
show
s
0000
Waiting for coolant temperature
0000
0001
Pre-heating
0000
1011
Post-heating
0000
1111
Intermediate heating
0000
0011
Standby-heating
0000
1011
Waiting for post-heating
0001
1111
Waiting for intermediate heating
0001
0000
Waiting for ECO start request (Economy)
0001
0101
No glow period
0000
1000
No heating for start-up
0000
1111
No heating
1111
0111
Heating for start-up
0000
1101
No post-heating
0000
100
Repair Group 01 - Vehicle self-diagnosis
Specification
1111 1111
xx,x s
Approx. battery voltage
80.0...110.0°C
Evaluation
⇒  P age 100
---
---
---