Section 3: Basic Operation
Guidelines for Using the CDP
• Press keys one-at-a time; there are no simultaneous key combinations required or allowed.
• Pause briefly between key presses to allow the projector to respond to the previous action.
• Hold the navigation keys for continuous adjustment or movement in one direction.
• If no key is pressed within 5 minutes while in a menu, the system will return to the Main menu. If editing text
or entering a numerical value, the entry will also be lost.
• Press EXIT once to cancel a selection or go back one level in the menu.
• If the back light turns off, push any key to turn it on again.

3.4.2 System Status and Alarm Conditions

There are three status LEDs on the CDP for the purpose of indicating projector status. Table 3.1 details the
various conditions of the LEDs and their meaning. In addition to the visual indicator of the LEDs, you can
check the status of specific projector components through the CDP Status menu.
Table 3.1 Status LEDs: Indicating Projector Status
ON
(GREEN)
Solid Green
Flashing
Green
Flashing
Green
OFF
Solid Green
Solid Green
Flashing
Green
On or Off
On or Off
If the projector encounters a system error or malfunction, the red ERROR LED will begin flashing. At this
point, press ENTER to display the alarm message on the CDP display. This acknowledges that you have seen
the message and the ERROR LED will turn a solid red. The ERROR LED will remain in this state until the
problem is resolved or a new error is encountered by the projector. If a safety interlock, content security lock or
DMD over-temperature fault occurs during operation, the ERROR LED will illuminate in the same way
however power to the lamp will automatically be turned OFF and the lamp button will remain disabled until
the problem is fixed.
3-6
READY (YEL-
ERROR
LOW)
(RED)
Solid Yellow
Solid Red
Flashing Yellow
Flashing Red
Solid Yellow
OFF
Solid Yellow
OFF
Solid Yellow
OFF
OFF
OFF
Flashing Yellow
OFF
On or Off
Flashing Red
On or Off
Solid Red
DESCRIPTION
Initial Power ON.
Flashes 3 times. Press and hold.
Power OFF button to stay in Failsafe Mode.
Warm Up (to Standby Mode)
Standby Mode.
Power is OFF.
Lamp is OFF.
Power is ON.
Lamp is OFF.
Power is ON.
Lamp is ON.
Cool Down (to Power On or Standby Mode).
New alarm condition detected (such as critical warning detected by
DMD temperature sensors).
Alarm condition exists, but has been acknowledged in the web user
interface or CDP.
CP2000-ZX Setup Guide
020-100098-04 Rev. 1 (06-2009)