2.5.4 TPC Alarm Window

In addition to the status bar at the bottom of any TPC screen, a full-screen red alarm window flashes if one of
the alarm conditions shown in the left column of Table 2.1 is encountered. If a safety interlock fails, power
will no longer reach the lamp (DC output is stopped), and the lamp button on the TPC Main menu will be
disabled. NOTES: 1) A failed safety interlock automatically prevents power from going to the lamp and
disables the lamp button on the TPC Main menu. Since most interlock alarm conditions are triggered by
switches, regularly check the operation of these switch levers. 2) With interlock integrity restored, the lamp
button on the TPC Main menu is automatically re-enabled.

Can Alarm Conditions Be Ignored?

Note every alarm window indicates a new condition. In a given session, the alarm window will not reappear
for a condition that you have acknowledged (shunted) but not yet solved. However, if you cycle the projector
OFF and ON again, any persisting alarm condition will trigger the alarm window again. Although it is highly
recommended that the monitored over-temperature and fan speed conditions always be set to trigger a flashing
alarm window (default), this trigger can be turned off if desired by clearing the appropriate Alarm Triggers
checkbox in the Advanced menu. Once cleared, such conditions will only trigger the yellow or red Status
warning button rather than a flashing alarm window. This can be helpful in rare cases where the alarm window
is erroneously/repeatedly triggered with no detectable error condition. Disabling alarm triggers is not
recommended for normal operation. Failed interlocks, an SSM communication fault, I
failures always produce an alarm window-i.e., these alarm triggers cannot be disabled or hidden.
CP2000-SB Setup Guide
020-100249-02 Rev. 1 (05-2009)
Identifies the
new alarm
condition.
Select to "shunt" (disable) this alarm
• Condition will persist until rectified, but will not trigger another alarm window.
• Acknowledgements are discarded upon on next TPC power-up - alarm window will re-appear.
Figure 2-4 Flashing Alarm Window
Section 2: Basic Operation
Blinking Red = New
Alarm Condition.
2
C fault, and lamp
2-7