Automatic Measurement Of Start Position; Automatic Setting Of Input Timing - IDK MSD-72 Series User Manual

4k@60 and hdcp 2.2 supported digital multi switcher
Hide thumbs Also See for MSD-72 Series:
Table of Contents

Advertisement

9.6.5 Automatic measurement of start position

Top → INPUT TIMING → AUTO START POS
Menu
Setting for
Each input channel, each input signal
Setting value ALL OFF
OFF
ON
The MSD monitors continuously the upper left of analog input video signal and it automatically matches the
upper left of the input video and the upper left of the screen.
Notes:
・For motion images, some content may not be displayed on the full screen, and the display position may be
moved every time the setting of the automatic measurement is applied. In such a case, set this menu to
"OFF". As "OFF" and "ON" are saved for each input signal, it can be set according to the input signal. If you
do not want to perform this function for all resolution, select "ALL OFF".
・Only the start position is set by automatic measurement of this menu. If "9.6.2 The total number of
horizontal dots (P.69)" and "9.6.4 Active area (P.70)" do not match, the lower right may be cut off or
blackout may be output. In this case, adjust the whole screen by following "9.6.3 Start position (P.69)". As
the set value must not exceed the value set in "9.6.3 Start position (P.69)", some input videos are
displayed with blackout at the left or top side.
・This menu is valid only if "[Figure 9.13] Conditions of automatic measurement" is satisfactory.
・Even if you set this menu to "ON", the manual setting will be applied and the automatic measurement is not
executed if you set any of the following menus: "9.6.2 The total number of horizontal dots", "9.6.3 Start
position", and "9.6.4 Active area". If you set "9.6.9 Tracking", the manual setting is applied, and tracing
is not set automatically when the automatic measurement is executed. When you execute "9.6.1
Automatic measurement", settings of this menu will be valid again.

9.6.6 Automatic setting of input timing

Top → INPUT TIMING → UNKNOWN TIMING
Menu
Setting for
None
Setting value AUTO SETUP ON [Default], AUTO SETUP OFF
The MSD loads the optimal table from the built- in table and converts signal. However, if unregistered signal is
input, the input timing must be set. By setting this menu to "AUTO SETUP ON", "9.6.1 Automatic
measurement" is executed and the input timing is set automatically if signal that cannot be detected by the
MSD are input for the first time.
Note:
If automatic measurement finds inconsistency of aspect ratio, please perform "9.6.1 Automatic
measurement" manually or set the input timing in "9.6.2 The total number of horizontal dots", "9.6.3 Start
position" and/or "9.6.4 Active area".
: not measuring all inputs from the input automatically
: not measuring the current input signal automatically
: measuring the current input signal automatically [Default]
71
MSD-72 Series User's Guide

Advertisement

Table of Contents
loading

Table of Contents