Automatic Measurement Of Start Position; Automatic Setting Of Input Timing - IDK MSD-501 User Manual

Hide thumbs Also See for MSD-501:
Table of Contents

Advertisement

MSD-501/502/701/702 User's Guide

7.7.5 Automatic measurement of start position

Menu
Top→INPUT TIMING→AUTO START POS
Setting for
Each input/input signal
Setting value ALL OFF
OFF
ON
Notes:
■ The MSD monitors continuously the upper left of analog input video signal and it automatically matches
the upper left of the input video and the upper left of the screen.
■ For motion images, some content may not be displayed on the full screen, and the display position may be
moved every time the setting of the automatic measurement is applied. In such a case, set this menu to
"OFF". As "OFF" and "ON" are saved for each input resolution, it can be set according to the input video. If
you do not want to perform this function for all resolution, select "ALL OFF".
■ Only the start position is set by automatic measurement of this menu. If "7.7.2 The total number of
horizontal dots" and "7.7.4 Active area" do not match, the lower right may be cut off or blackout may be
output. In this case, adjust the whole screen by following "7.7.1 Automatic measurement". As the set
value must not exceed the value set in "7.7.3 Start position", some input videos are displayed with
blackout at the left or top side.
■ This menu is valid only if [Fig. 7.9] Conditions of automatic measurement is satisfactory.
■ Even if you set this menu to "ON", the manual setting will be applied and the automatic measurement is
not executed if you set any of the following menus: "7.7.2 The total number of horizontal dots", "7.7.3
Start position", and "7.7.4 Active area". If you set "7.7.9 Tracking", the manual setting is applied, and
tracing is not set automatically when the automatic measurement is executed.
When you execute "7.7.1 Automatic measurement", settings of this menu will be valid again.

7.7.6 Automatic setting of input timing

Menu
Top→INPUT TIMING→UNKNOWN TIMING
Setting value AUTO SETUP ON [Default], AUTO SETUP OFF
The MSD loads the optimal table from the built- in table and converts signal. However, if unregistered signal is
input, the input timing must be set. By setting this menu to "AUTO SETUP ON", "7.7.1Automatic
measurement" is executed and the input timing is set automatically if signal that cannot be detected by the
MSD are input for the first time.
Note:
If automatic measurement finds inconsistency of aspect ratio, please perform "7.7.1Automatic
measurement" manually or set the input timing in "7.7.2 The total number of horizontal dots", "7.7.3 Start
position", and "7.7.4 Active area".
48
: not measuring all inputs from the input automatically
: not measuring the current input signal automatically
: measuring the current input signal automatically [Default]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msd-701Msd-502Msd-702

Table of Contents