3.3.6 Input timing

@AIS / @AIT
Setting
Description
Command
Response
Setting
Description
Command
Response
Parameter
Setting
Command
example
Response
Description
Setting
Command
example
Response
Description
Setting
Command
example
Response
Description
Remarks
MSD-701UHD / 702UHD / 801UHD/ 802UHD Command Guide
Automatic measurement
Starting automatic measurement of the start position and display period.
@AIS, ch
@AIS, ch
Starting automatic measurement with a desired aspect ratio.
@AIT, ch (, mode)
@AIT, ch (, mode)
ch: Input channel
6 = IN6, 7 = IN7
mode: Measurement mode
-1 = NEXT ASPECT, 0 = 4:3, 1 = 5:4, 2 = 5:3, 3 = 16:9, 4 = 16:10
If you select "NEXT ASPECT", the next aspect ratio will be selected in order every
time the automatic measurement is executed. If you do not set any mode
parameter, "NEXT ASPECT" mode will be applied.
@AIS,7
@AIS,7
Starting the automatic measurement of IN7 the start position and display period.
@AIT,7,0
@AIT,7,0
Starting the automatic measurement of IN7 input timing setting at the aspect ratio
of "4:3".
@AIS,7
@ERR,7
If the automatic measurement fails, an error is returned.
These commands are valid only if analog RGB/analog YPbPr signal is input.