Komatsu PW98MR-10 Operation & Maintenance Manual page 202

Wheeled excavator
Table of Contents

Advertisement

MACHINE OPERATIONS AND CONTROLS
When adding fuel, never spill the fuel or let it overflow. The fuel may cause fire.
If any fuel has spilled, wipe it up completely. If fuel has spilled over soil or sand, remove that soil or
sand.
Fuel is highly flammable and dangerous. Never bring any open flame near fuel.
Never leave the machine unattended during the refilling and check.
After each overflow or fuel leaks, check the machine to detect that there are no fuel traces next to
the electrical or high temperature components.
Do not dry up the refilling pump. Monitor the fuel level during refilling, in order to avoid pump dry
up.
Check that the filter placed at the end of the pipe is clean.
In case of malfunction of the refilling automatic stop system, consult the Komatsu local Distributor
and do not use the system until the problem is solved.
When the machine is operate on sites without fuel tank and
pump, the machine can be refuelled by the refilling pump with
fuel barrels. The refuelling pump is placed on the side cover.
1.
Check that battery disconnect switch (S) is in ON position
(I).
2.
Insert the key into starting switch and turn it to ON position
(B).
3-134