OPERATION
If there is any error existing, "!" is displayed on top of switch F5.
Press switch F5 to check the detail of the error. Current abnor-
mality screen is displayed.
WARNING DISPLAY FOR ABNORMALITIES AND FAULTS
NOTICE
When any of action levels "L01" to "L04" is displayed on the machine monitor, there is abnormality in
the machine.
Take appropriate actions following the list of action level displays and remedies.
The caution lamp that lights up in red when an action level is displayed warns operator to stop the ma-
chine urgently, stop or pause the current operation.
If no action is taken, the machine can be seriously affected. Take necessary actions immediately.
(1) Caution lamp
(2) Caution lamp
(3) Caution lamp
Standard screen (camera display and meter display)
When 1 type of caution is generated, it is displayed on caution lamp (1).
When 1 types of caution are generated, they are displayed on caution lamps (1) and (2).
When 2 types of caution are generated, they are displayed on caution lamps (1), (2), and (3).
When 3 types or more of caution are generated, they are displayed on caution lamps (1), (2), and (3) alternately
at intervals of 2 seconds.
(4) Action level display
(5) Caution lamp
WENAM00061
EXPLANATION OF COMPONENTS
RKA47820
3-15