EXPLANATION OF COMPONENTS
Operations with the camera screen when the controls locking lever is raised
The following is the method of changing the camera image display on the monitor.
•
On standard screen AA, the camera image is always displayed on the left part of the monitor.
•
On standard screen AA, when switch F3 is pressed, camera image full-screen display NN is displayed.
Camera image full-screen display NN is displayed on the entire screen.
•
If the lock lever is at L (LOCK) (raised) position, when switch F3 is pressed on camera image full-screen
display NN, message screen PP is displayed and no camera image is displayed.
•
On message screen PP, when switch F3 is pressed or when no switch is operated for 10 seconds, standard
screen AA is displayed.
•
On message screen PP, when switch F5 is pressed, the message disappears and meter display screen QQ
is displayed.
REMARK
When the lock lever is at F (FREE) (lowered) position, message screen AA is displayed.
To enable the camera for full screen and vice-versa quickly it is also possible to use the button on the right joy-
stick.
3-56
WENAM00061
OPERATION