MACHINE OPERATIONS AND CONTROLS
2)
The screen changes to the working mode and travel
speed display screen after approximately 2 seconds,
and then it changes to the standard screen.
Engine coolant temperature gauge (6)
Engine coolant temperature caution lamp (7)
Fuel gauge (8)
Fuel level caution lamp (9)
3)
If an alarm indicator light (10) remains on red, immedi-
ately check the alarm of the corresponding indicator
light.
For details see "CAUTION LAMP LIST FOR ABNOR-
MALITIES AND FAULTS (3-17)".
4)
If the maintenance due time has passed for certain
items, maintenance time caution lamp (11) is lit in red
for 30 seconds.
5)
Press user menu display switch (12), check the item
which has exceeded the maintenance interval, and
perform maintenance immediately.
For details see "MAINTENANCE SCREEN SETTING
(3-76)".

METHOD FOR STARTING ENGINE

METHOD FOR STARTING ENGINE IN NORMAL WEATHER
Start the engine only while sitting down in the operator's seat.
Do not attempt to start the engine by short-circuiting the engine starting circuit.
Doing so may cause a fire or serious personal injury or death.
Check that there are no persons or obstacles in the surrounding area, then sound the horn and start
the engine.
Exhaust gas is toxic.
When starting the engine in confined spaces, be particularly careful to ensure good ventilation.
Keep the engine hood and covers closed during operation unless you are checking the machine.
3-148
k
k
WARNING
WENAM00061
OPERATION
RKA48960
RKA48970
RKA48980