Parameter Descriptions
15-32 Alarm Log: Time
Array [10]
Range:
0 s
[0 - 2147483647 s] View the time when the logged event
*
3
3
3.16.5 15-4* Drive Identification
Parameters containing read only information about the
hardware and software configuration of the frequency
converter.
15-40 FC Type
Range:
0
[0 - 6 ] View the frequency converter type. The read-out is
*
15-41 Power Section
Range:
0
[0 - 20 ] View the FC type. The read-out is identical to the
*
15-42 Voltage
Range:
0
[0 - 20 ] View the FC type. The read-out is identical to the
*
15-43 Software Version
Range:
0
[0 - 5 ] View the combined SW version (or 'package
*
15-44 Ordered Typecode String
Range:
0
[0 - 40 ] View the type code string used for re-ordering the
*
15-45 Actual Typecode String
Range:
0
[0 - 40 ]
*
15-46 Frequency Converter Ordering No
Range:
0
[0 - 8 ] View the 8-digit ordering number used for re-
*
156
Function:
occurred. Time is measured in seconds
from frequency converter start-up.
Function:
identical to the FC 300 Series power field of the
type code definition, characters 1-6.
Function:
FC 300 Series power field of the type code
definition, characters 7-10.
Function:
FC 300 Series power field of the type code
definition, characters 11-12.
Function:
version') consisting of power SW and control SW.
Function:
frequency converter in its original configuration.
Function:
View the actual type code string.
Function:
ordering the frequency converter in its original
configuration.
®
VLT
AutomationDrive FC 301/302 Programming Guide
15-47 Power Card Ordering No
Range:
0
[0 - 8 ]
*
15-48 LCP Id No
Range:
0
*
15-49 SW ID Control Card
Range:
0
[0 - 20 ] View the control card software version number.
*
15-50 SW ID Power Card
Range:
0
[0 - 20 ]
*
15-51 Frequency Converter Serial Number
Range:
0
[0 - 10 ]
*
15-53 Power Card Serial Number
Range:
0
[0 - 19 ]
*
15-58 Smart Setup Filename
Range:
Size related
15-59 CSIV Filename
Range:
Size related
3.16.6 15-6* Option Ident.
This read-only parameter group contains information about
the hardware and software configuration of the options
installed in slots A, B, C0 and C1.
15-60 Option Mounted
Array [8]
Range:
0
*
15-61 Option SW Version
Array [8]
Range:
0
[0 - 20 ]
*
MG33MI02 - Rev. 2013-11-20
Function:
View the power card ordering number.
Function:
[0 - 20 ]
View the LCP ID number.
Function:
Function:
View the power card software version number.
Function:
View the frequency converter serial number.
Function:
View the power card serial number.
Function:
[0 - 20 ] Shows the currently used smart
*
application setup filename.
Function:
[0 - 16 ] Shows the currently used CSIV
*
(Costumer Specific Initial Values)
filename.
Function:
[0 - 30 ]
View the installed option type.
Function:
View the installed option software version.
Need help?