Parameter Descriptions
13-44 Logic Rule Boolean 3
Array [6]
Option:
[78]
Digital input x30/4
[79]
Digital input x46/1
3
3
[80]
Digital input x46/3
[81]
Digital input x46/5
[82]
Digital input x46/7
[83]
Digital input x46/9
[84]
Digital input x46/11
[85]
Digital input x46/13
[90]
ATEX ETR cur. warning Selectable, if parameter 1-90 Motor
[91]
ATEX ETR cur. alarm
[92]
ATEX ETR freq.
warning
[93]
ATEX ETR freq. alarm
[94]
RS Flipflop 0
[95]
RS Flipflop 1
[96]
RS Flipflop 2
[97]
RS Flipflop 3
[98]
RS Flipflop 4
[99]
RS Flipflop 5
[100] RS Flipflop 6
[101] RS Flipflop 7
[102] Relay 1
138
®
VLT
AutomationDrive FC 301/302 Programming Guide
Function:
Thermal Protection is set to [20]
ATEX ETR or [21] Advanced ETR. If
the alarm 164 ATEX ETR
cur.lim.alarm is active, the output
is 1.
Selectable, if parameter 1-90 Motor
Thermal Protection is set to [20]
ATEX ETR or [21] Advanced ETR. If
the alarm 166 ATEX ETR
freq.lim.alarm is active, the output
is 1.
Selectable, if parameter 1-90 Motor
Thermal Protection is set to [20]
ATEX ETR or [21] Advanced ETR. If
the alarm 163 ATEX ETR
cur.lim.warning is active, the
output is 1.
Selectable, if parameter 1-90 Motor
Thermal Protection is set to [20]
ATEX ETR or [21] Advanced ETR]. If
the warning 165 ATEX ETR
freq.lim.warning is active, the
output is 1.
See parameter group 13-1*
Comparators
See parameter group 13-1*
Comparators
See parameter group 13-1*
Comparators
See parameter group 13-1*
Comparators
See parameter group 13-1*
Comparators
See parameter group 13-1*
Comparators
See parameter group 13-1*
Comparators
See parameter group 13-1*
Comparators
MG33MI02 - Rev. 2013-11-20
13-44 Logic Rule Boolean 3
Array [6]
Option:
[103] Relay 2
[104] Relay 3
X47/MCB 113
[105] Relay 4
X47/MCB 113
[106] Relay 5
X47/MCB 113
[107] Relay 6
X47/MCB 113
[108] Relay 7
X34/MCB 105
[109] Relay 8
X34/MCB 105
[110] Relay 9
X34/MCB 105
3.14.7 13-5* States
13-51 SL Controller Event
Array [20]
Option:
[0]
False
Select the boolean input (TRUE or
FALSE) to define the Smart Logic
Controller event. See
parameter 13-01 Start Event ([0] -
[61]) and parameter 13-02 Stop
Event ([70] - [74]) for further
description.
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current Limit
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[10]
Out of speed range
[11]
Below speed low
[12]
Above speed high
[13]
Out of feedb. range
[14]
Below feedb. low
[15]
Above feedb. high
[16]
Thermal warning
[17]
Mains out of range
[18]
Reversing
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip lock)
[22]
Comparator 0
[23]
Comparator 1
[24]
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
Function:
Function: