Parameter Descriptions
0-32 Custom Readout Max Value
Range:
100 Custom-
[ par. 0-31 -
ReadoutUnit
999999.99
*
CustomRea-
doutUnit]
0-37 Display Text 1
Range:
Function:
0
[0 -
Enter a text which can be viewed in the graphical
*
25 ]
display by selecting [37] Display Text 1 in
parameter 0-20 Display Line 1.1 Small, 0-21 Display
Line 1.2 Small, 0-22 Display Line 1.3 Small,
0-23 Display Line 2 Large or 0-24 Display Line 3
Large.
0-38 Display Text 2
Range:
Function:
0
[0 -
Enter a text which can be viewed in the graphical
*
25 ]
display by selecting [38] Display Text 2 in
parameter 0-20 Display Line 1.1 Small, 0-21 Display
Line 1.2 Small, 0-22 Display Line 1.3 Small,
0-23 Display Line 2 Large or 0-24 Display Line 3
Large.
0-39 Display Text 3
Range:
Function:
0
[0 -
Enter a text which can be viewed in the graphical
*
25 ]
display by selecting [39] Display Text 3 in
parameter 0-20 Display Line 1.1 Small, 0-21 Display
Line 1.2 Small, 0-22 Display Line 1.3 Small,
0-23 Display Line 2 Large or 0-24 Display Line 3
Large.
3.2.5 0-4* LCP Keypad
Enable, disable and password protect individual keys on
the LCP.
0-40 [Hand on] Key on LCP
Option:
Function:
[0] Disabled
No effect when [Hand On] is pressed. Select
[0] Disabled to avoid accidental start of the
frequency converter in Hand on mode.
[1] Enabled
The LCP switches to Hand on mode directly
when [Hand on] is pressed.
[2] Password
After pressing [Hand on] a password is
required. If parameter 0-40 [Hand on] Key on
LCP is in included in My Personal Menu, define
®
VLT
AutomationDrive FC 301/302 Programming Guide
Function:
This parameter sets the max
value to be shown when the
speed of the motor has reached
the set value for 4-13 Motor
Speed High Limit [RPM] or
parameter 4-14 Motor Speed High
Limit [Hz] (depends on setting in
parameter 0-02 Motor Speed
Unit).
MG33MI02 - Rev. 2013-11-20
0-40 [Hand on] Key on LCP
Option:
Function:
the password in parameter 0-65 Quick Menu
Password. Otherwise define the password in
0-60 Main Menu Password.
[3] Hand Off/On When [Hand On] is pressed once, the LCP
switches to Off mode. When pressed again,
the LCP switches to Hand on mode.
[4] Hand Off/On
Same as [3] but a password is required (see
w. Passw.
option [2] Password).
[9] Enabled, ref
= 0
0-41 [Off] Key on LCP
Option:
Function:
[0] Disabled
Avoids accidental stop of the frequency converter.
[1] Enabled
[2] Password Avoids unauthorised stop. If parameter 0-41 [Off]
Key on LCP is included in the Quick Menu, then
define the password in parameter 0-65 Quick Menu
Password.
0-42 [Auto on] Key on LCP
Option:
Function:
[0] Disabled
Avoid accidental start of the frequency converter
in Auto mode.
[1] Enabled
[2] Password Avoids unauthorised start in Auto mode. If
parameter 0-42 [Auto on] Key on LCP is included in
the Quick Menu, then define the password in
parameter 0-65 Quick Menu Password.
0-43 [Reset] Key on LCP
Option:
Function:
[0] Disabled
No effect when [Reset] is pressed. Avoids
accidental alarm reset.
[1] Enabled
[2] Password
Avoids unauthorised resetting. If
parameter 0-43 [Reset] Key on LCP is included
in the Quick Menu, then define the password
in parameter 0-65 Quick Menu Password.
[7] Enabled
Resets the frequency converter without setting
without OFF
it in Off mode.
[8] Password
Resets the frequency converter without setting
without OFF
it in Off mode. A password is required when
pressing [Reset] (see [2]).
3
3
33