Danfoss VLT AutomationDrive FC 302 Programming Manual page 206

Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

Parameter Lists
Par. No. # Parameter description
17-20
Protocol Selection
17-21
Resolution (Positions/Rev)
17-24
SSI Data Length
17-25
Clock Rate
17-26
SSI Data Format
4
4
17-34
HIPERFACE Baudrate
17-5* Resolver Interface
17-50
Poles
17-51
Input Voltage
17-52
Input Frequency
17-53
Transformation Ratio
17-56
Encoder Sim. Resolution
17-59
Resolver Interface
17-6* Monitoring and App.
17-60
Feedback Direction
17-61
Feedback Signal Monitoring
4.1.21 18-** Data Readouts 2
Par. No. # Parameter description
18-3* Analog Readouts
18-36
Analog Input X48/2 [mA]
18-37
Temp. Input X48/4
18-38
Temp. Input X48/7
18-39
Temp. Input X48/10
18-6* Inputs & Outputs 2
18-60
Digital Input 2
18-9* PID Readouts
18-90
Process PID Error
18-91
Process PID Output
18-92
Process PID Clamped Output
Process PID Gain Scaled
18-93
Output
4.1.22 30-** Special Features
Par. No. # Parameter description
30-0* Wobbler
30-00
Wobble Mode
30-01
Wobble Delta Frequency [Hz]
30-02
Wobble Delta Frequency [%]
Wobble Delta Freq. Scaling
30-03
Resource
30-04
Wobble Jump Frequency [Hz]
30-05
Wobble Jump Frequency [%]
30-06
Wobble Jump Time
204
®
VLT
AutomationDrive FC 301/302 Programming Guide
Default value
4-set-up
[0] None
All set-ups
ExpressionLimit
All set-ups
13 N/A
All set-ups
ExpressionLimit
All set-ups
[0] Gray code
All set-ups
[4] 9600
All set-ups
2 N/A
1 set-up
7 V
1 set-up
10 kHz
1 set-up
0.5 N/A
1 set-up
[0] Disabled
1 set-up
[0] Disabled
All set-ups
[0] Clockwise
All set-ups
[1] Warning
All set-ups
Default value
4-set-up
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 %
All set-ups
0 %
All set-ups
0 %
All set-ups
0 %
All set-ups
Default value
4-set-up
[0] Abs. Freq., Abs.
Time
All set-ups
5 Hz
All set-ups
25 %
All set-ups
[0] No function
All set-ups
0 Hz
All set-ups
0 %
All set-ups
ExpressionLimit
All set-ups
MG33MI02 - Rev. 2013-11-20
FC 302
Change
Conver-
only
during
sion index
operation
FALSE
-
FALSE
0
FALSE
0
FALSE
3
FALSE
-
FALSE
-
FALSE
0
FALSE
-1
FALSE
2
FALSE
-1
FALSE
-
FALSE
-
FALSE
-
TRUE
-
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
-3
TRUE
0
TRUE
0
TRUE
0
FALSE
0
FALSE
-1
FALSE
-1
FALSE
-1
FALSE
-1
FC 302
Change
Conver-
only
during
sion index
operation
FALSE
-
TRUE
-1
TRUE
0
TRUE
-
TRUE
-1
TRUE
0
TRUE
-3
Type
Uint8
Uint32
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Type
Int32
Int16
Int16
Int16
Uint16
Int16
Int16
Int16
Int16
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16