Parameter Descriptions
15-62 Option Ordering No
Array [8]
Range:
Function:
0
[0 - 8 ] Shows the ordering number for the installed
*
options.
15-63 Option Serial No
Array [8]
Range:
Function:
0
[0 - 18 ]
View the installed option serial number.
*
15-70 Option in Slot A
Range:
Function:
0
[0 - 30 ] View the type code string for the option installed
*
in slot A, and a translation of the type code
string. E.g. for type code string 'AX' the translation
is 'No option'.
15-71 Slot A Option SW Version
Range:
Function:
0
[0 - 20 ] View the software version for the option installed
*
in slot A.
15-72 Option in Slot B
Range:
Function:
0
[0 - 30 ] View the type code string for the option installed
*
in slot B, and a translation of the type code string.
E.g. for type code string 'BX' the translation is 'No
option'.
15-73 Slot B Option SW Version
Range:
Function:
0
[0 - 20 ] View the software version for the option installed
*
in slot B.
15-74 Option in Slot C0/E0
Range:
Function:
0
[0 - 30 ] View the type code string for the option installed
*
in slot C, and a translation of the type code string.
E.g. for type code string 'CXXXX' the translation is
'No option'.
15-75 Slot C0/E0 Option SW Version
Range:
Function:
0
[0 - 20 ] View the software version for the option installed
*
in slot C.
15-76 Option in Slot C1/E1
Range:
Function:
0
[0 - 30 ] Displays the type code string for the option in
*
slot C1. (CXXXX if no option) and the translation
i.e. >No option<.
®
VLT
AutomationDrive FC 301/302 Programming Guide
15-77 Slot C1/E1 Option SW Version
Range:
0
[0 - 20 ] Displays the software version for the installed
*
15-80 Fan Running Hours
Range:
0 h
[0 - 2147483647
*
h]
15-81 Preset Fan Running Hours
Range:
0 h
[0 - 99999
*
h]
15-89 Configuration Change Counter
Range:
0
[0 - 65535 ]
*
3.16.7 15-9* Parameter Info
15-92 Defined Parameters
Array [1000]
Range:
0
[0 - 9999 ] View a list of all defined parameters in the
*
15-93 Modified Parameters
Array [1000]
Range:
0
[0 - 9999 ] View a list of the parameters that have been
*
15-98 Drive Identification
Range:
0
[0 - 40 ] This parameter contains data that is used by the
*
MG33MI02 - Rev. 2013-11-20
Function:
option in option slot C.
Function:
View how many hours the heatsink
fan has run (increments for each
hour). The value is saved when the
frequency converter is turned off.
Function:
Enter value to preset the Fan Running
Hours counter, see parameter 15-80 Fan
Running Hours.
This parameter cannot be selected via the
serial port, RS-485.
Function:
NOTICE
This parameter cannot be adjusted while
the motor is running.
Function:
frequency converter. The list ends with 0.
Function:
changed from their default setting. The list
ends with 0. Changes may not be visible until
up to 30 s after implementation.
Function:
MCT 10 Set-up Software.
3
3
157

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AutomationDrive FC 302 and is the answer not in the manual?

This manual is also suitable for:

Vlt automationdrive fc 301

Table of Contents

Save PDF