3.20.4 30-8* Compatibility
30-80 d-axis Inductance (Ld)
Range:
Size
3
3
related
1000.000 mH]
*
30-81 Brake Resistor (ohm)
Range:
Size
[ 0.01 -
related
65535.00
*
Ohm]
30-83 Speed PID Proportional Gain
Range:
Size related
*
30-84 Process PID Proportional Gain
Range:
0.100
[0 - 10 ] Enter the process controller proportional gain.
*
170
Function:
[0.000 -
Enter the value of the d-axis
inductance. Obtain the value from
the permanent magnet motor data
sheet. The d-axis inductance cannot
be found by performing an AMA.
Function:
Set the brake resistor value in Ω. This
value is used for monitoring the power
to the brake resistor in
parameter 2-13 Brake Power Monitoring.
This parameter is only active in
frequency converters with an integral
dynamic brake.
Function:
[0 - 1 ] Enter the speed controller proportional
gain. Quick control is obtained at high
amplification. However if amplification is
too great, the process may become
unstable.
Function:
Quick control is obtained at high amplification.
However if amplification is too great, the
process may become unstable.
®