Parameter Descriptions
16-36 Inv. Nom. Current
Range:
Function:
data are used for calculation of
torque, motor protection, etc.
16-37 Inv. Max. Current
Range:
Function:
Size
[0.01 -
View the inverter maximum current,
related
10000 A]
which must match the nameplate
*
data on the connected motor. The
data are used for calculation of
torque, motor protection, etc.
16-38 SL Controller State
Range:
Function:
0
[0 - 100 ] View the state of the event under execution by
*
the SL controller.
16-39 Control Card Temp.
Range:
Function:
0 °C
[0 - 100 °C] View the temperature on the control card,
*
stated in °C
16-40 Logging Buffer Full
Option: Function:
View whether the logging buffer is full (see parameter
group 15-1* Data Log Settings). The logging buffer is
never full when setting parameter 15-13 Logging Mode
to [0] Log always.
[0] No
[1] Yes
16-41 Logging Buffer Full
Range:
0
[0 - 50 ]
*
16-45 Motor Phase U Current
Range:
Function:
0 A
[0 - 10000 A] Displays the Motor Phase U
*
Facilitates monitoring of imbalance in the
motor currents, detection of weak motor
cables or imbalance in motor windings.
16-46 Motor Phase V Current
Range:
Function:
0 A
[0 - 10000 A] Displays the Motor Phase V
*
Facilitates monitoring of imbalance in the
motor currents, detection of weak motor
cables or imbalance in motor windings.
16-47 Motor Phase W Current
Range:
Function:
0 A
[0 - 10000 A] Displays the Motor Phase W
*
Facilitates monitoring of imbalance in the
®
VLT
AutomationDrive FC 301/302 Programming Guide
3.17.3 16-5* Ref. & Feedb.
Function:
current.
RMS
current.
RMS
current.
RMS
MG33MI02 - Rev. 2013-11-20
16-47 Motor Phase W Current
Range:
Function:
motor currents , detection of weak motor
cables or imbalance in motor windings.
16-48 Speed Ref. After Ramp [RPM]
Range:
Function:
0 RPM
[-30000 - 30000
This parameter specifies the
*
RPM]
reference given to the frequency
converter after the speed ramp.
16-49 Current Fault Source
Range:
Function:
0
[0 - 8 ] Value indicates source of current faults including
*
short circuit, over current, and phase imbalance
(from left):
1-4 Inverter
5-8 Rectifier
0 No fault recorded
16-50 External Reference
Range:
Function:
0
[-200 - 200 ] View the total reference, the sum of digital,
*
analog, preset, bus and freeze references, plus
catch-up and slow-down.
16-51 Pulse Reference
Range:
Function:
0
[-200 - 200 ] View the reference value from programmed
*
digital input(s). The readout can also reflect
the impulses from an incremental encoder.
16-52 Feedback[Unit]
Range:
0 Reference-
[-999999.999 -
FeedbackUnit
999999.999
*
ReferenceFeed-
backUnit]
16-53 Digi Pot Reference
Range:
Function:
0
[-200 - 200 ] View the contribution of the Digital Potenti-
*
ometer to the actual reference.
Function:
View the feedback unit
resulting from the selection
of unit and scaling in
parameter 3-00 Reference
Range,
parameter 3-01 Reference/
Feedback Unit,
parameter 3-02 Minimum
Reference and
parameter 3-03 Maximum
Reference.
161
3
3