Servo Control Signal; Servo Control Input (Nc To Servo) - Mitsubishi Electric MDS-E Series Instruction Manual

Table of Contents

Advertisement

MDS-E/EH Series Instruction Manual
5 Servo Adjustment

5.7 Servo Control Signal

The sequence input/output signals exchanged between the NC and servo drive unit are explained in this section. The
status of each signal is displayed on the NC SERVO MONITOR screen.

5.7.1 Servo Control Input (NC to Servo)

(1) Servo control input 1
Name
Servo control input 1
bit0.
READY ON command (RDY)
Status turns to ready ON at RDY=1.
bit1.
Servo ON command (SRV)
[1]
Drive unit turns ON at SRV=1 (servo ON status).
[2]
Drive unit turns OFF at SRV=0 (servo OFF status).
bit4.
Position loop gain changeover command (KPM)
[1]
The position loop gain (SV049/SV050/SV058) for spindle synchronous (synchronoustapping,
synchronous control with spindle C-axis, etc.) is selected at KPM=1.
[2]
The normal position loop gain (SV003/SV004/SV057) is selected at KPM=0.
bit6.
Excessive error detection width changeover command (EOM)
[1]
The excessive error width (SV053) for the special control (initial absolute position setting,stopper
control, etc.) is selected at EOM =1.
[2]
The normal excessive error width (SV023) is selected at EOM =0.
bit7.
Alarm reset command (ALMR)
NR alarm is reset at ALMR=1.
bit8.
Current limit selection command (IL1)
[1]
The current (torque) limit (SV014) for the special control (initial absolute position setting,stopper
control, etc.) is selected at IL1 =1.
[2]
The normal current (torque) limit (SV013) is selected at IL1 =0.
(Note)
The bits other than those above are used for maintenance.
IB-1501229-F
Details
F
E
D
C
B
A
9
8
7
IL1
EOM
ALMR
bit
Details
0
RDY
READY ON command
SRV
Servo ON command
1
(For maintenance)
2
-
3
-
(For maintenance)
Position loop gain changeover command
4
KPM
5
-
(For maintenance)
Excessive error detection width changeover command
6
EOM
7
ALMR
Alarm reset command
8
IL1
Current limit selection command
-
(For maintenance)
9
A
-
(For maintenance)
B
-
(For maintenance)
C
-
(For maintenance)
(For maintenance)
D
-
E
-
(For maintenance)
F
-
(For maintenance)
6
5
4
3
2
1
0
KPM
SRV
RDY
314