MDS-E/EH Series Instruction Manual
8 Maintenance
[3-2] Use the cleaning jigs to clean the air ducts of the spindle motor frame.
Insert the cleaning jigs A and B into the motor frame's air ducts from the counter-load side of the spindle motor,
scrape out the dirt, and wipe it off with wastes, etc.
(4) Assembling
[1]
After all the cleaning processes have been completed, attach the cooling fan unit to the motor in the order opposite
to that of the detachment process.
[2]
Precautions in installing cooling fan unit
(a) The section where the cooling fan lead wires are led out must be in the state without a space by inserting a
protection tube for the cooling fan. A space could lead to faults of the motor by allowing foreign matters enter
there.
IB-1501229-F
Spindle motor
Counter-load side of the spindle motor
View C-C
Motor frame's air ducts (cleaning points)