Mitsubishi Electric MDS-E Series Instruction Manual page 249

Table of Contents

Advertisement

MDS-E/EH Series Instruction Manual
4 Setup
#13024
SP024 INP
Set the in-position detection width.
Set the positioning accuracy required to the machine.
Lower setting value increases the positioning accuracy, but makes the cycle time (settling time) longer.
The standard setting is "875".
---Setting range---
0 to 32767 (1°/1000)
#13025
SP025 INP2
Use this when detecting an in-position different from normal in-position width such as advancing the in-posi-
tion signal. The adjustment procedure is the same as SP024 (INP).
The standard setting is "875".
---Setting range---
0 to 32767 (1°/1000)
(PR)
#13026
SP026 TSP
Set the maximum motor speed.
If the motor speed exceeds the set maximum speed, an overspeed alarm will occur.
---Setting range---
1 to 32767 (r/min)
#13027
SP027 ZSP
Set the motor speed for detecting zero speed.
If the motor speed drops below the set speed, the zero speed signal turns ON.
The standard setting is "50".
---Setting range---
1 to 1000 (r/min)
#13028
SP028 SDTS
Set the motor speed for detecting the speed.
If the motor speed drops below the set speed, the speed detection signal turns ON.
The standard setting is 10% of the maximum motor speed.
---Setting range---
10 to 32767 (r/min)
#13029
SP029 SDTR
Set the hysteresis width in which the speed detection changes from ON to OFF.
If the setting value is small, the speed detection will chatter easily.
The standard setting is "30".
---Setting range---
10 to 1000 (r/min)
#13030
SP030 SDT2
Set the specified speed of the specified speed output.
When carrying out digital output of the specified speed output, set SP229/bitC to "1".
It is not available for MDS-EJ-SP Series.
---Setting range---
0 to 32767 (r/min)
(PR)
#13031
SP031 MTYP
Set the control system of the spindle drive unit.
2200: Semi closed loop control
4200: Full closed loop control by using spindle side ABZ pulse output encoder
6200: Full closed loop control by using spindle side serial output encoder
IB-1501229-F
In-position width
2nd in-position width
Maximum motor speed
Motor zero speed
Speed detection set value
Speed detection reset width
2nd speed detection setting value
Motor type
218

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents