Mitsubishi Electric MDS-E Series Instruction Manual page 247

Table of Contents

Advertisement

MDS-E/EH Series Instruction Manual
4 Setup
(PR)
#13018
SP018 SPEC2
Select the spindle specification.
A function is allocated to each bit.
Set this in hexadecimal format.
bit F-A :
Not used. Set to "0".
bit 9 : mpg Earth fault detection
0: Disable
Set "0" and it is constantly "Enable" for MDS-EJ-SP Series.
bit 8 : spsu Command speed limit value
0: 33,750 r/min
bit 7-6 :
Not used. Set to "0".
bit 5 : mkch Coil switch function
0: Disable 1: Enable
bit 4-2 :
Not used. Set to "0".
bit 1 : oplp Open loop control
This allows the operation in which no encoder feedback signals are used.
It is used when adjusting the encoder, etc.
0: Disable 1: Enable
bit 0 :
Not used. Set to "0".
IB-1501229-F
1: Enable (standard)
1: 135,000 r/min
Spindle specification 2
oplp
mkch
spsu
mpg
216

Hide quick links:

Advertisement

Table of Contents
loading