Mitsubishi Electric MDS-E Series Instruction Manual page 69

Table of Contents

Advertisement

MDS-E/EH Series Instruction Manual
1 Installation
(3) Installing the sensor section
[1]
Prepare the notched fitting section at the machine side's installation
position to be of the specified dimensions in advance.
[2]
With the sensor installation seat's R section butted against the
notched fitting section, fix the sensor installation seat with a
mounting screw (M4 × 0.8 screws). A locking agent should be
applied on the mounting screw before it is tightened.
[3]
Fix the sensor with its R section butted against the notched fitting
section so that the position relation between the detection gear and
sensor is kept constant. This ensures favorable accuracy of the
sensor installation.
[4]
Keep the deviation of the sensor center and outer diameter center of
the detection gear to ±0.25mm or less. If the center deviation cannot
be directly measured, set so that the dimension from the sensor
installing surface to the outer diameter edge of the detection gears is
19.0±0.25mm. (Some detection gears have thickness at the inner
diameter section.)
[5]
Make sure that force is not constantly applied on the sensor's lead
wires.
[6]
Check the gap between the encoder sensor and the gear (0.3±0.05mm).
POINT
To install the sensor section, the notched fitting section on the machine side must have the specified dimensions.
The sensor's installation accuracy is assured by adjusting the outside dimensions of the notched fitting section.
3.0mm
Butt the back side of the sensor installation seat
against here
Butt the R section of the sensor installation seat
against here
Notched section's
outer diameter
Sensor series type
TS5690N64xx
TS5690N90xx
TS5690N12xx
TS5690N19xx
TS5690N25xx
IB-1501229-F
2-M4×0.8 screw
 
Screw holes' height
from the rotation center
 
Shape of notched fitting section
Installing dimension of the sensor section
Screw holes' height from the
rotation center (mm)
36.7
47.1
62.3
87.9
113.5
38
Installing the detector
39mm
 
 
 
Notched section's
outer diameter
Notched fitting section's outer
diameter (mm)
-0.030
Φ59.4
-0.070
0
Φ79.2
-0.040
+0.025
Φ108.8
-0.015
+0.005
Φ159.4
-0.035
+0.040
Φ210.2
0
Sensor installation surface
Lead wire
Sensor installation seat
R section
13.0mm
19.0mm ± 0.25mm
To the end of the outer diameter
Z phase
side
 
 

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents