MDS-E/EH Series Instruction Manual
9 Power Backup System
(3) Parameter setting of servo drive unit
When using the retraction function at power failure, set the servo parameter of this function for the servo drive unit
connected to the power supply unit.
【#2236(PR)】 SV036 PTYP Power supply type/ Regenerative resistor type
MDS-E/EH Series: Power supply type
When connecting a power supply unit, set a code for each power supply unit.
bit F-C : amp
Set the power backup function to be used.
No function used : 0
Retraction function at power failure : C
(4) Parameter setting of spindle drive unit
When using the retraction function at power failure, set the spindle parameter of this function for the spindle drive
unit connected to the power supply unit.
【#13032(PR)】 SP032 PTYP Power supply type/ Regenerative resistor type
MDS-E/EH Series: Power supply type
When connecting a power supply unit, set a code for each power supply unit.
bit F-C : amp
Set the power backup function to be used.
No function used : 0
Retraction function at power failure : C