Wiring Of Deceleration And Stop Function At Power Failure - Mitsubishi Electric MDS-E Series Instruction Manual

Table of Contents

Advertisement

MDS-E/EH Series Instruction Manual
9 Power Backup System

9.1.2 Wiring of Deceleration and Stop Function at Power Failure

: Main circuit
: Control circuit
Circuit
protector
R
S
T
Ground
(Note 1) When multiple power supply units are used, each power supply unit must be connected with one power
backup unit. It is not possible to connect multiple power supply units to one power backup unit.
(Note 2) Select the power supply that can be retained until the completion of deceleration stop operation for the
24V power supply of dynamic brake unit and MP scale.
(Note 3) In the system with multiple power supply units, each power supply unit must be connected with one
power backup unit.
(Note 4) Connect the control power supply (L11,L21) of the unit where the deceleration and stop function is not
used to a commercial AC power supply.
CAUTION
Connect the PFU's TE3 (OUT-L11, OUT-L21) to L11 and L21 of each unit. Do not connect them to a commercial AC power
supply. The unit will be damaged if connecting the PFU's TE3 to a commercial AC power supply. When retrofitting the PFU,
disconnect commercial AC power from L11, L21.
MDS-E/EH-CV
CN4
CN41
AC
Contactor
reactor
L1
TE1
L2
L3
L+
TE2
MC
MC1
L -
CN23
MC2
L11
TE3
L21
Circuit
protector
Ground
MDS-E/EH-SP
MDS-D/DH-PFU
MDS-E/EH-Vx
CN4
TE2
TE2
L+
L+
L-
L-
TE3
TE3
L11
L11
L21
L21
Ground
Ground
447
R-UNIT
10A
AL1
CN43
10B
AL2
CN41
R1
R1
TE5
R2
R2
L+
TE2
L-
TE3
OUT- L11
OUT- L21
L1
TE1
L2
L3
Ground
IB-1501229-F