Mitsubishi Electric MDS-E Series Instruction Manual page 173

Table of Contents

Advertisement

MDS-E/EH Series Instruction Manual
4 Setup
#2233
SV033 SSF2
Select the servo functions.
A function is assigned to each bit.
Set this in hexadecimal format.
bit F : lmc2a Lost motion compensation 2 timing
0: Normal
bit E : zup Vertical axis pull up function
0: Stop
1: Enable
Related parameters: SV032, SV095
bit D : rps Safely limited speed setting increment
Change the setting units of the specified speed signal output speed (SV073).
0: mm/min
Related parameters: SV073
bit C-8 :
Not used. Set to "0".
bit 7-5 : nfd2 Depth of Notch filter 2
Set the depth of Notch filter 2 (SV046).
bit7,6,5=
000: -∞
001: -18.1[dB]
010: -12.0[dB]
011: -8.5[dB]
100: -6.0[dB]
101: -4.1[dB]
110: -2.5[dB]
111: -1.2[dB]
bit 4 : fhz3 Notch filter 3
0: Stop
1: Start (1125Hz)
bit 3-1 : nfd1 Depth of Notch filter 1
Set the depth of Notch filter 1 (SV038).
bit3,2,1=
000: -∞
001: -18.1[dB]
010: -12.0[dB]
011: -8.5[dB]
100: -6.0[dB]
101: -4.1[dB]
110: -2.5[dB]
111: -1.2[dB]
bit 0 :
Not used. Set to "0".
IB-1501229-F
1: Change
1: 100mm/min
Servo function 2
nfd1
fhz3
nfd2
rps
zup
lmc2a
142

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents