3 Safety Function
[3] Parameter setting
Input observation for dedicated wiring STO signal is set with the parameter SV113,SP229/bit8. The following
parameter setting is not to enable or disable the shutoff function of STO function performed by the H/W.
When using network STO function only, make sure to set to "0".
< Servo parameter >
【#2313】 SV113 SSF8 Servo function 8
bit 8 : sto Dedicated wiring STO function
0: Dedicated wiring STO function unused
< Spindle parameter >
【#13229】 SP229 SFNC9 Spindle function 9
bit 8 : sto Dedicated wiring STO function
0: Dedicated wiring STO function unused
IB-1501229-F
1: Dedicated wiring STO function used
1: Dedicated wiring STO function used