Synchronous Tapping Adjustment - Mitsubishi Electric MDS-E Series Instruction Manual

Table of Contents

Advertisement

MDS-E/EH Series Instruction Manual
6 Spindle Adjustment

6.1.5 Synchronous Tapping Adjustment

(1) Gain setting and time constant determination
[1]
For speed loop gain during synchronous tapping, speed loop gain set 2, which consists of SP008 (speed loop
gain 2), SP009 (speed loop lead compensation 2), and SP010 (speed loop delay compensation 2), is used.
Thus, SP035 has to be set as follows. For position loop gain, set standard 33 to SP002 (position loop gain
interpolation mode).
< List of parameters used for adjustment >
< Related servo parameters >
Set the spindle and interpolation axis by tapping.
[2]
Create a NC program so that the synchronous tapping operation program has 3000r/min of spindle rotation
speed, 1mm (equivalent of M6 screw) of screw pitch size, and depths at which the following two different
operation patterns are generated.
(Note that the operation conditions, such as spindle rotation speed and screw pitch, may be specified by the
machine tool builder.)
Operation pattern 1
Operation pattern 2
IB-1501229-F
Parameter
SP002
Value in SP005 set at "Gain Adjustment"
SP008
SP009
SP010
SP035
0200: Speed loop gain set 2 selection (Validate bit9)
Parameter
SV049
Set the same value as spindle parameter "SP002"
SV050
Set it when using SHG control (when not using, set to "0")
SV058
Set it when using SHG control (when not using, set to "0")
Adjust depth so that motor rotation speed waveform shapes trapezoids
Adjust depth so that motor rotation speed waveform shapes mountain-valley
Setting value
33
(Initial setting value: 150)
1900
0
Setting value
Spindle rotation speed (r/min)
Constant speed area
Spindle rotation speed (r/min)
No constant speed area
338
Time (sec)
Time (sec)