Mitsubishi Electric MDS-E Series Instruction Manual page 263

Table of Contents

Advertisement

MDS-E/EH Series Instruction Manual
4 Setup
#13075
SP075 DWSH
Set the slip frequency scale during deceleration.
Normally, set to "0". (For Mitsubishi adjustment)
---Setting range---
0 to 255 (1/16-fold)
#13076
SP076 DWSL
Set the slip frequency scale at deceleration when using the low-speed coil.
Normally, set to "0". (For Mitsubishi adjustment)
---Setting range---
0 to 255 (1/16-fold)
#13077
SP077 IQA
Set the current loop gain.
To use the coil switch function, set the current loop gain for when the high-speed coil is selected.
The setting value is determined by the motor's electrical characteristics so that the value is fixed to each mo-
tor used.
Set the value given in the spindle parameter list. (For Mitsubishi adjustment)
---Setting range---
1 to 20480
#13078
SP078 IDA
Set the current loop gain.
To use the coil switch function, set the current loop gain for when the high-speed coil is selected.
The setting value is determined by the motor's electrical characteristics so that the value is fixed to each mo-
tor used.
Set the value given in the spindle parameter list. (For Mitsubishi adjustment)
---Setting range---
1 to 20480
#13079
SP079 IQG
Set the current loop gain.
To use the coil switch function, set the current loop gain for when the high-speed coil is selected.
The setting value is determined by the motor's electrical characteristics so that the value is fixed to each mo-
tor used.
Set the value given in the spindle parameter list. (For Mitsubishi adjustment)
---Setting range---
1 to 8192
#13080
SP080 IDG
Set the current loop gain.
To use the coil switch function, set the current loop gain for when the high-speed coil is selected.
The setting value is determined by the motor's electrical characteristics so that the value is fixed to each mo-
tor used.
Set the value given in the spindle parameter list. (For Mitsubishi adjustment)
---Setting range---
1 to 8192
#13081
SP081 IQAL
When using coil switch function, set the current loop gain for when the low-speed coil is selected.
The setting value is determined by the motor's electrical characteristics so that the value is fixed to each mo-
tor used.
Set the value given in the spindle parameter list. (For Mitsubishi adjustment)
---Setting range---
1 to 20480
IB-1501229-F
Slip compensation scale during regeneration high-
speed coil
Slip compensation scale during regeneration low-
speed coil
Q axis current lead compensation
D axis current lead compensation
Q axis current gain
D axis current gain
Q axis current lead compensation low-speed coil
232

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents